Part Number Hot Search : 
2SC6084 K34SA24 PT22A3 TGH10A MB100 JMB355 SI4472DY IRLU7833
Product Description
Full Text Search
 

To Download AD1036-12FS Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 AD1048FS Series
Very Low Cost, 36 - 48W DIN Rail Mount Single Output AC/DC Power Supplies
New Industrial Supplies!!
Key Features:
* 36W - 48W Output Power * DIN Rail Mountable * Universal AC Input * UL 508 Compliant * EN60950 Compliant * 12, 15, 24 & 48 VDC Outputs * Cond./Rad. EMI Class B * >170 kH MTBF * LOW COST!
Electrical Specifications
Specifications typical @ +25C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter Input Voltage Range Input Frequency Inrush Current, Cold Start Leakage Current 110 VAC 220 VAC 264 VAC Conditions Min. Conditions Universal Min. 100 127 47 Typ. Max. 240 370 63 Units VAC VDC Hz A A mA Units % % % % mSec % mS % %/C
22 44 1.8
Output
Parameter Output Voltage Accuracy Output Voltage Adjustment Range Line Regulation Load Regulation (Note 1) Hold Time Ripple & Noise (20 MHz) (Note 2) Output Power Protection Transient Recovery Time (Note 3) Transient Response Deviation Temperature Coefficient Output Short Circuit Typ. Max. 0.5 10.0 Vin = Min to Max 1.0 Iout = 20% to 100% 1.0 110 VAC, Full Load 10 220 VAC, Full Load 20 See Model Selection Guide Power Limit 130 160 2 50% Load Change 5 0.04 0.05 Continuous With Autorecovery Min. 3,000 2,000 500 100 Typ. Max.
RoHS Compliant
General
Parameter Isolation Voltage Isolation Resistance (Note 4) Switching Frequency Conditions Input - Output Input - FG (Frame Ground) Output - FG (Frame Ground) 500 VDC Fixed Conditions Units VAC M kHz
MicroPower Direct
292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: sales@micropowerdirect.com W: www.micropowerdirect.com
66
Environmental
Parameter Operating Temperature Range Storage Temperature Range Cooling Humidity Vibration Min. Typ. Max. Units -20 +25 +50 C -20 +85 C Free Air Convection RH, Non-condensing 95 % 10 Hz ~ 2 kHz; 2G 10 min./1 Cycle; X, Y, Z axis each 1 hour Ambient 3.54 x 2.54 x 1.77 Inches (90.0 x 64.5 x 44.0 mm) Plastic Screw Terminal Conditions MIL HDBK 217F, 25C, Gnd Benign Min. Typ. Max. Units 170 kHours UL 1950, EN 60950, IEC 60950 Compliance to EN55011, EN55022 (CISPR22) Class B EN6100-4-2,3,4,5,6,8,11 Level 3
Physical
Case Size Case Material Connection
Reliability Specifications
Parameter MTBF Safety Standards EMI Compliance EMS Immunity Compliance
Model Selection Guide
Model Number AD1036-12FS AD1045-15FS AD1048-24FS AD1048-48FS Rated Power (W) 36 45 48 48 Input Voltage (VAC) Current (A) Voltage (VDC) 12 15 24 48 Output Current (A) Max) 3.0 3.0 2.0 1.0 Current (A) Range 0 ~ 3.0 0 ~ 3.0 0 ~ 2.0 0 ~ 1.0 Overvoltage Protection (VDC) 20.0 20.0 40.0 60.0 Efficiency (%, Typ) 80 81 83 83 Fuse Rating Slow-Blow (A) 2.0 2.0 2.0 2.0
Universal Range 115 VAC 230 VAC 100 - 240 1.0 0.5 100 - 240 1.0 0.5 100 - 240 1.0 0.5 100 - 240 1.0 0.5
Notes: 1. Load regulation is specified for a load change of 20% to 100%. 2. Ripple & noise is measured using equipment with 20 Mhz of bandwidth with the unit under test operating at rated load and a 110 VAC input. Connection to the unit is made with a 0.1 F / 630V metalized capacitor & a 47 F electrolytic capacitor connected in parallel. 3. Transient recovery is measured to within a 1% error band for a load step change of 50% to 100%. 4. Isolation resistance is given for Input/Output and Input/FG. For Output/FG., it is 50 M 5. Overload protection is power limiting. The unit recovers automatically when the fault is removed. 6. Over voltage protection is a shut down type. The unit recovers automatically when the fault is removed. 7. To mount the unit to the DIN rail, tilt the unit rearwards from the top, fitting the mount over the top of the rail. Press back on the bottom front of the unit until it locks in place on the rail. To remove the unit from the rail, pull the removal clip at the bottom rear of the unit downward with a screw driver. With the clip down, lift up on the unit from the bottom front until it clears the rail. Before installation or removal all wiring should be disconnected and the main power to the system shut off. 8. When wiring the supply, all lines should be as thick and short as possible. AWG 14 wire is recommended for the AD1048FS series. 9. The units should be mounted so they are vertically orientated. Air flow (if it is provided) would optimally flow from the bottom to the top of the unit. 10. It is recommended that a fuse be used on the input of a power supply for protection. See the table above for the correct rating.
Derating Curve
Mechanical Dimensions
Terminal Connections
Pin 1 2 3 4 5 Function DC Output (+V) DC Output (-V) Frame Ground (FG) AC/Neutral AC/Live
Notes: * All dimensions are typical in inches (mm) * Tolerance x.xx = 0.01 (0.25)
MicroPower Direct
www.micropowerdirect.com
*
292 Page Street Ste D Stoughton, MA 02072
TEL: (781) 344-8226
*
FAX: (781) 344-8481
*
E-Mail: sales@micropowerdirect.com


▲Up To Search▲   

 
Price & Availability of AD1036-12FS

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .